Hydrogen Leak Detection
For Facility Safety Monitoring

Four Channel Wall Mount Controller
Beacon 410 Model


Note:
4-channel panel described. Also available in 1-, 2-, and
8-channel versions.

The Beacon 410 is a highly configurable, microprocessor-based, flexible and easy to use gas monitor. It simultaneously displays the gas type, readings, and status for 4 channels of gas detection. It can monitor any combination of direct connect sensors (LEL combustibles, Oxygen, Hydrogen Sulfide, Carbon Monoxide, and Carbon Dioxide) as well as any 4-20mA transmitters.

Each channel has 2 fully configurable alarm points with dedicated configurable relays and a built-in silenceable buzzer alarm. There are 5 common relays that can be configured as additional channel relays allowing up to 3 alarm relays per channel.

Outputs include a 4-20mA signal for each channel and a digital (RS425) signal for remote logging of data via a Modbus network. A Min-Max feature retains high & low peak readings for review at any time.

Field calibration is made simple by the easy to use Calibration Mode. An optional high visibility strobe can be mounted on the controller. The unit can be powered from 115/220 VAC, an external 24 VDC source, or a 24 VDC backup battery.

All features and functions of the Beacon 410 are controlled by easy to use menus on the backlit LCD display. The form-C (SPDT) relay contacts are rated at 10A, 250V, reducing or eliminating the need for additional slave relays. All features of the Beacon 410 are built into the unit so you never need to purchase or maintain any “add-on” cards or components.

back to top

 

Specifications
Dimensions:
Height: 12.5”
Width: 11”
Depth: 6.4”
Enclosure:
NEMA 4X non-metallic for indoor and outdoor locations
Conduit Connection:
3/4” NPT conduit hubs (4) for sensor, power & relay wiring
Wiring Termination:
Screw type terminal block, 14 gauge max
Power:
115 VAC & 220 VAC, or 24 VDC nominal, battery backup option available
Controls:

Display PCB Control Switches:

  • UP/YES push button switch
  • DOWN/NO push button switch
  • ESCAPE push button switch
  • ENTER push button switch
  • External reset switch
  • On/Off toggle switch
ENVIRONMENTAL
Operating Temp:
-4°F to 122°F (-20°C to 50°C)
Storage Temp:
-4°F to 158°F (-20°C to 70°C)
Relative Humidity
0 - 95% RH (non-condensing)
Enclosure:
NEMA-4X Non-metallic enclosure, chemical and weather resistant
INPUTS
Sensors:
Hydrogen, LEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide, and Carbon Dioxide.
4-20 mA Sensors:

Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of sensors are available - please inquire. See List Below.
Wiring distances up to 8,000 feet.

Sampling Methods:
Diffusion or Sample Draw
OUPUTS
Relays:
Two flexible, programmable Form-C (C, NO, NC) relays per channel, plus five common relays (Fail, Alarm-1, Alarm-2, Alarm-3, Alarm-Any). Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel. 10A contact rating.
4-20 mA:
Signal output, 4-20 mA (maximum load impedance 500 ohms), per channel
RS-485:
Modbus format RS-485 serial output of all channel data including gas reading and alarm status.
Display:
4 x 20 backlit LCD display
Audible:
Built-in buzzer alarm, 94 dB, mounted on enclosure
Coded output: pulsing = gas alarm, steady = fail
Visual:
1.
Alarm LEDs (on Display PCB)
Alarm 1, yellow
Alarm 2, orange
Alarm 3, red
Fail, yellow
2.
Green Pilot LED to indicate AC power connected
(on Display PCB)
3.
An optional 24 VDC NEMA 4X strobe mounted to
top of case.

Specifications subject to change without notice.
Made in the USA

back to top

Technical Assistance
Contact:
Jay Fitzgerald or Blair Simmons
E-mail:
info@fuelcellsensor.com
Address:
Argus Group
46400 Continental Dr.
Chesterfield, Michigan 48047 USA
Telephone:

586-840-3200 (local)
1-800-873-0456 (toll free)

Fax:
586-840-3201

back to top

System Block Diagram

back to top

Available Sensors

We offer a large variety of sensor types for use with hydrogen related activities.

See chart below:

Explosion Proof LEL
Explosion Proof O2
Sensor Type
Range
Hydrogen Specific:
0—100% LEL
0—2000 ppm
Combustible Gases:
0—100% LEL
0—100% Vol
Carbon Monoxide:
0—300 ppm
Oxygen:
0—25% Vol
Hydrogen Sulfide:
0—100 ppm
Carbon Dioxide:
0—5% Vol
Contact us for more information on available sensors.

back to top

 Applications
  • Fuel Cell Testing Facilities
  • Battery Charging Stations
  • Laboratories
  • Manufacturing facilities
  • Automotive
  • Research
  • Petrochemical plants
  • Refineries
  • Water & wastewater treatment pants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • HVAC

back to top

Features
  • Simultaneously monitor up to 4 channels
  • Digital display of all 4 channels
  • Accepts direct connect sensors for LEL / O2 / H2S / CO / CO2
  • Accepts any 4-20 mA transmitter, 2 or 3 wire
  • 2 programmable alarm levels per channel standard
  • 5 configurable alarm relays common to system
  • Zero follower automatically compensates sensor drift
  • 4-20 mA analog & Modbus digital output
  • 115 / 220 VAC or 24 VDC operation
  • Buzzer alarm with silence feature
  • Alarm reset switch
  • Built in trouble alarm with relay
  • Weather proof NEMA 4X enclosure
  • Optional strobe & battery backup available

back to top

Accessories
Facility Monitoring System products may include the following:
  • Calibration Kit
  • A/V Alarms
  • Back Up Power Supply
  • Sample-Draw Adapter
  • Remote Calibration Adapter
  • Data Logging
  • Graphic Display

 

Support Services
Argus offers a variety of support services, including:
  • Installation
  • Calibration
  • Field Service
  • I. H. Consultation
  • Training
back to top

 



Automotive | Leak Detection | Facility Safety Monitoring | Calibration

Partner Sites
Calibration Gas | Detector Rentals | Detector Sales | Fixed Systems Monitoring

Information: Send Us E-mail

 

Copyright 2001~2010 Argus Group. All rights reserved.

Specifications

Technical Assistance

System Block Diagram

Available Sensors

Applications

Features

Accessories & Support