| Partner
Sites:
Calibration
Gas
Detector
Rentals
Detector
Sales
Fixed
Systems
Monitoring
Send
Us E-mail
|
Hydrogen
Leak Detection
For Facility Safety Monitoring
Four
Channel Wall Mount Controller
Beacon 410 Model |
Note:
4-channel panel described. Also available in 1-, 2-, and
8-channel versions.
The
Beacon 410 is a highly configurable, microprocessor-based,
flexible and easy to use gas monitor. It simultaneously displays
the gas type, readings, and status for 4 channels of gas detection.
It can monitor any combination of direct connect sensors (LEL
combustibles, Oxygen, Hydrogen Sulfide, Carbon Monoxide, and
Carbon Dioxide) as well as any 4-20mA transmitters.
Each
channel has 2 fully configurable alarm points with dedicated
configurable relays and a built-in silenceable buzzer alarm.
There are 5 common relays that can be configured as additional
channel relays allowing up to 3 alarm relays per channel.
Outputs
include a 4-20mA signal for each channel and a digital (RS425)
signal for remote logging of data via a Modbus network. A
Min-Max feature retains high & low peak readings for review
at any time.
Field
calibration is made simple by the easy to use Calibration
Mode. An optional high visibility strobe can be mounted on
the controller. The unit can be powered from 115/220 VAC,
an external 24 VDC source, or a 24 VDC backup battery.
All
features and functions of the Beacon 410 are controlled by
easy to use menus on the backlit LCD display. The form-C (SPDT)
relay contacts are rated at 10A, 250V, reducing or eliminating
the need for additional slave relays. All features of the
Beacon 410 are built into the unit so you never need to purchase
or maintain any “add-on” cards or components.
back
to top
|
| Specifications |
| Dimensions: |
Height:
12.5”
Width: 11”
Depth: 6.4” |
| Enclosure:
|
NEMA
4X non-metallic for indoor and outdoor locations |
| Conduit
Connection:
|
3/4”
NPT conduit hubs (4) for sensor, power & relay wiring
|
| Wiring
Termination:
|
Screw
type terminal block, 14 gauge max |
| Power: |
115
VAC & 220 VAC, or 24 VDC nominal, battery backup option
available |
| Controls: |
Display
PCB Control Switches:
- UP/YES
push button switch
- DOWN/NO
push button switch
- ESCAPE
push button switch
- ENTER
push button switch
- External
reset switch
- On/Off
toggle switch
|
| ENVIRONMENTAL |
Operating
Temp: |
-4°F
to 122°F (-20°C to 50°C) |
Storage
Temp: |
-4°F
to 158°F (-20°C to 70°C) |
Relative
Humidity |
0
- 95% RH (non-condensing) |
Enclosure: |
NEMA-4X Non-metallic enclosure, chemical and weather resistant
|
| INPUTS |
Sensors: |
Hydrogen,
LEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide, and Carbon Dioxide.
|
4-20
mA Sensors: |
Accepts
any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety
of sensors are available - please inquire. See
List Below.
Wiring distances up to 8,000 feet. |
| Sampling
Methods: |
Diffusion
or Sample Draw |
| OUPUTS
|
Relays: |
Two
flexible, programmable Form-C (C, NO, NC) relays per channel,
plus five common relays (Fail, Alarm-1, Alarm-2, Alarm-3, Alarm-Any).
Common relays may optionally be assigned to function as additional
channel alarm relays, providing for up to three alarm relays
per channel. 10A contact rating. |
4-20
mA: |
Signal
output, 4-20 mA (maximum load impedance 500 ohms), per channel
|
RS-485: |
Modbus
format RS-485 serial output of all channel data including gas
reading and alarm status. |
| Display: |
4
x 20 backlit LCD display |
Audible: |
Built-in
buzzer alarm, 94 dB, mounted on enclosure
Coded output: pulsing = gas alarm, steady = fail
|
Visual: |
| 1. |
Alarm
LEDs (on Display PCB) |
| |
Alarm
1, yellow
Alarm 2, orange
Alarm 3, red
Fail, yellow |
| 2.
|
Green
Pilot LED to indicate AC power connected
(on Display PCB) |
| 3. |
An optional 24 VDC NEMA 4X strobe mounted to
top of case. |
|
Specifications
subject to change without notice.
Made in the USA
back
to top
|
| Technical
Assistance |
| Contact: |
Jay
Fitzgerald or Blair Simmons |
| E-mail: |
info@fuelcellsensor.com |
| Address: |
Argus
Group 46400
Continental Dr.
Chesterfield,
Michigan 48047 USA |
| Telephone: |
586-840-3200
(local)
1-800-873-0456
(toll free) |
| Fax: |
586-840-3201 |
back
to top

back
to top
| Available
Sensors |
|
We
offer a large variety of sensor types for use with hydrogen
related activities.
See
chart below: |
|
Explosion
Proof LEL |
Explosion
Proof O2 |
|
| Sensor
Type |
Range |
| Hydrogen
Specific: |
0—100%
LEL
0—2000 ppm |
| Combustible
Gases: |
0—100%
LEL
0—100% Vol |
| Carbon
Monoxide: |
0—300
ppm |
| Oxygen: |
0—25%
Vol |
| Hydrogen
Sulfide: |
0—100
ppm |
| Carbon
Dioxide: |
0—5%
Vol |
| Contact
us for more information on available sensors. |
back
to top
|
| Applications |
- Fuel
Cell Testing Facilities
- Battery
Charging Stations
- Laboratories
- Manufacturing
facilities
- Automotive
- Research
- Petrochemical
plants
- Refineries
- Water
& wastewater treatment pants
- Pulp
& paper mills
- Gas,
telephone, & electric utilities
- HVAC
back
to top
|
| Features |
- Simultaneously
monitor up to 4 channels
- Digital
display of all 4 channels
- Accepts
direct connect sensors for LEL / O2 / H2S / CO / CO2
- Accepts
any 4-20 mA transmitter, 2 or 3 wire
- 2
programmable alarm levels per channel standard
- 5
configurable alarm relays common to system
- Zero
follower automatically compensates sensor drift
- 4-20
mA analog & Modbus digital output
- 115
/ 220 VAC or 24 VDC operation
- Buzzer
alarm with silence feature
- Alarm
reset switch
- Built
in trouble alarm with relay
- Weather
proof NEMA 4X enclosure
- Optional
strobe & battery backup available
back
to top
|
| Accessories |
| Facility
Monitoring System products may include the following: |
| |
- Calibration
Kit
- A/V
Alarms
- Back
Up Power Supply
- Sample-Draw
Adapter
- Remote
Calibration Adapter
- Data
Logging
- Graphic
Display
|
|
| Support
Services |
| Argus
offers a variety of support services, including: |
| |
- Installation
- Calibration
- Field
Service
- I.
H. Consultation
- Training
|
| back
to top |
|
|
Partner
Sites
Calibration
Gas | Detector Rentals
| Detector
Sales | Fixed
Systems Monitoring
Information:
Send Us E-mail
Copyright
2001~2010 Argus Group. All rights reserved. |
Specifications
Technical
Assistance
System
Block Diagram
Available
Sensors
Applications
Features
Accessories
& Support
|